Caple C804C Especificações Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 150
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Introduction Revision 8
1–8
Input
Impedance
50
Noise Figure
8 dB typical, 10 dB maximum @ maximum gain (15 dB for HPOD Ku-Band)
with BUC Option
25 dB
VSWR
1.25:1 Maximum
with BUC Option
1.50:1 Maximum
Connector
Type ‘N’
Sample Ports
Output Sample
Type N, 50Ω, -40 dBc nominal
Input Sample
Type N, 50Ω, -20 dBc nominal
Remote Control
COM Port
EIA-485 or EIA-232
Alarms
Summary Fault
Form C
Environmental
Operating Temp.
-40° to +55°C (-40° to 131°F)
Non-operating Temp.
-50° to +75°C (-58° to 167°F)
Operating Humidity
0% to 100% condensing
Altitude
10,000 ft above sea level (derated 2°C/ 1000 ft AMSL)
Power Requirements
180 to 264 VAC, 47 Hz to 63 Hz (typical)
Physical
Dimensions
26.77L x 17.88W x 11.49H inches (67.99L x 45.41W x 29.18H cm)
Weight
75 lbs (34 kg) nominal
Available Options
Optional BUC
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 149 150

Comentários a estes Manuais

Sem comentários