DIP SWITCHES - SETTING SCSI ID
If you have just one DD1500x-II, you need not concern yourself with this too much as the correct SCSI ID
will have been set at the factory. The default settings for a single drive is SCSI ID#0 and the rear panel DIP
switches should look like this:
However, if you install another drive into the DD1500x-II, the DIP switches should be set as appropriate.
1
ON
2 4
OFF
DRIVE 1
124
DRIVE 2
1
ON
2 4
OFF
DRIVE 1
124
DRIVE 2
ID Numbers
DIP Switches
124
0 OFF OFF OFF
1 ON OFF OFF
2 OFF ON OFF
3 ON ON OFF
4 OFF OFF ON
5 ON OFF ON
6 OFF ON ON
7ONONON
SCSI ID#0 is still selected for the first drive. SCSI ID#1 has been set for the second (you may, of course, set
any SCSI ID you like as long as it does not contend with any others on the buss).
Note: In the DD1500 system, the DD1500m is set to SCSI ID #7. Select the ID numbers
other than ID #7.
If you are using other drives in the system, then termination for the second disk in the DD1500x-II should be
switched off (remove the terminator of accessory from connector) and the other drives terminated or
otherwise as appropriate.
If you are in any doubt about SCSI IDs and termination, please consult your dealer. Similarly, if you are in
any doubt about setting up a system with more than one drive, please consult your dealer who will be able to
advise you.