Digital Fiber Sensor FX-100 SERIES
130
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
Fiber Sensor
Amplifiers
FX-300
FX-100
Fibers
FT / FD / FR
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
FIBER
SENSORS
FX-100
Fiber Sensor
Amplifi ers
Lens (For thru-beam type fi ber)
Designation Model No. Description
For thru-beam type fi ber
Expansion
lens
(Note 1)
FX-LE1
Increases the sensing
range by 5 times or more.
• Ambient temperature:
–
60 to +350 °C
–
76 to +662 °F
(Note 3)
Sensing range (mm
in) [Lens on both sides]
Amplifi er
Fiber
FX-101□ FX-102□
FT-B8 2,200 86.614
3,500 137.795 (Note 2)
FT-FM2, FT-T80 3,000 118.110
3,500 137.795 (Note 2)
FT-R80 1,900 74.803
3,500 137.795 (Note 2)
FT-W8 3,000 118.110
3,500 137.795 (Note 2)
FT-P80, FT-P60
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-P81X 1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H35-M2 2,000
78.740
3,500 137.795 (Note 2)
FT-H20W-M1 1,300 51.181 1,600 62.992 (Note 2)
FT-H20-M1 1,600
62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S
1,000 39.370
3,500 137.795 (Note 2)
Super-
expansion
lens
(Note 1)
FX-LE2
Tremendously increases the
sensing range with large
diameter lenses.
• Ambient temperature:
–
60 to +350 °C
–
76 to +662 °F
(Note 3)
Sensing range (mm
in) [Lens on both sides]
Amplifi er
Fiber
FX-101□ FX-102□
FT-B8, FT-FM2, FT-R80, FT-W8, FT-P80, FT-P60
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-P81X 1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H35-M2
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-H20W-M1, FT-H20-M1
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H13-FM2
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
Side-view
lens
FX-SV1
Beam axis is bent by 90°.
• Ambient temperature:
–
60 to +300 °C
–
76 to +572 °F
(Note 3)
Sensing range (mm
in) [Lens on both sides]
Amplifi er
Fiber
FX-101□ FX-102□
FT-B8 530 20.866 1,450 57.087
FT-FM2, FT-T80 550 21.654 1,700 66.929
FT-W8 450 17.717 1,300 51.181
FT-P80 420 16.535 1,400 55.118
FT-P60 300 11.811 850 33.465
FT-P81X 550 21.654 1,700 66.929
FT-H35-M2 280 11.024 800 31.496
FT-H20W-M1 140 5.512 400 15.748
FT-H20-M1 280 11.024 840 33.071
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S
150 5.906 410 16.142
Expansion
lens for vacuum-
resistant fi ber
(Note 1)
FV-LE1
Sensing range increases by
4 times or more.
• Ambient temperature:
–
60 to +350 °C
–76 to +662 °F
(Note 3)
Sensing range (mm
in) [Lens on both sides] (Note 4)
Amplifi er
Fiber
FX-101□ FX-102□
FT-H30-M1V 450 17.717 1,600 62.992
Side-view
lens for
vacuum-
resistant fi ber
FV-SV2
Beam axis is bent by 90°.
• Ambient temperature:
–
60 to +300 °C
–76 to +572 °F
(Note 3)
Sensing range (mm
in) [Lens on both sides] (Note 4)
Amplifi er
Fiber
FX-101□ FX-102□
FT-H30-M1V 450 17.717 1,600 62.992
Notes: 1) Be careful when installing the thru-beam type fi ber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is diffi cult.
Especially when installing a fi ber with many cores (sharp bending fi bers and heat-resistant glass fi ber), please be sure to use it only after you have
adjusted it suffi ciently.
2) The fi ber cable length practically limits the sensing range to 3,500 mm
137.795 in long (FT-H20W-M1, FT-P81X and FT-H20-M1: 1,600 mm 62.992 in).
3) For details on the ambient temperatures for the fi bers which being combined, refer to p.101~.
4) The fi ber cable length for the FT-H30-M1V is 1 m
3.281 ft. The sensing ranges in FX-102□ (long sensing range type) take into account the length of the
FT-J8 atmospheric side fi ber.
FIBER OPTIONS
The dimensions are on p.120~.
Comentários a estes Manuais