l ISOLATE ELECTRIC SUPPLY, OIL SUPPLY AND WATER SUPPLY (BOILER MODELS),
BEFORE COMMENCING WORK.
BOILER MODELS (OCB AND OEB)
IMPORTANT NOTE: The boiler must be removed completely and the supply pipework either
removed or suitably capped. This plumbing works need to be carried out PRIOR to the oil to
electric conversion.
AGA OCB MODELS (2 OVEN MODELS WITH BOILER)
Isolate water supply, disconnect, drain and remove boiler completely from cooker. Remove or cap-off supply pipework.
NOTE: The exisiting barrel, burner chamber and burner housing can be re-used for this conversion.
AGA OEB MODELS (4 OVEN MODELS WITH BOILER)
POST-2000 OEB MODELS
Remove boiler and pipework. NOTE: A NEW BARREL WILL BE REQUIRED.
PRE-2000 OEB MODELS: (OLDER 4-OVEN MODELS WITH BOILER)
After the boiler and connecting pipework have been removed and suitably capped, these models will require, A NEW
BARREL, A NEW BURNER CHAMBER AND NEW BURNER HOUSING TO BE FITTED.
OIL TO ELECTRIC CONVERSION INSTRUCTIONS